Medical testing supplies, diagnostic rapid test kits online USA - Lochness Medical Inc.
  • Home
  • Products
    • Harm Reduction
      • Fentanyl (FYL) Testing
      • Xylazine (XYL) Testing
      • Medetomidine (MED) Testing
      • Nitazene (NTZ) Testing
      • Benzodiazepine (BZO) Testing
      • Microscoops
      Drug Screening
      • Workflow Solutions
      • Urine
      • Saliva
      • ESA Tests
      Alcohol
      • Saliva
      • Urine
      Spiked Drink Detection
      • Spiked Drink Testing
      Infectious Diseases
      • COVID-19
      • Strep A
      • RSV
      • H. pylori
      Urinalysis
      • Urinary Tract Infection
      • Analyzers
      • Reagent Strips
      • Controls (UA)
      Women's Health
      • Pregnancy
      Cancer Screening
      • Colon Cancer Screening (FIT)
      Accessories
      • Urine Specimen Cups
      • Specimen Collection Accessories
      • Gloves
      • Misc
  • Harm Reduction
  • Services
  • About Us
  • Blog
  • Contact Us
  • Log In
    • Log in

    • New Customer? Request an account.
  • Order Form
close×
 
Home Blogs Introducing Xylazine 2.0: An Improved Xylazine Test Strip
Sections

Introducing Xylazine 2.0: An Improved Xylazine Test Strip

Innovation Harm Reduction Drug Screening
Introduction

Xylazine, originally developed as a veterinary sedative and analgesic, has increasingly become a cause for concern due to its emerging role as a drug of abuse. While primarily intended for use in animals, the drug's psychoactive properties have led to its illicit use in human populations. This trend raises significant public health and safety issues, as the misuse of xylazine poses various risks and challenges.

The emergence of Xylazine as a drug of abuse is characterized by its illicit use in combination with other substances, such as opioids, to enhance the effects of these drugs. This has been observed particularly in certain regions where the availability of xylazine is high. Its sedative and muscle-relaxant properties, when abused, can lead to a range of adverse effects, including respiratory depression, cardiovascular complications, and central nervous system depression.

One of the notable concerns is the association of xylazine with opioid misuse, contributing to the opioid epidemic. The combined use of xylazine and opioids can result in heightened sedation and respiratory depression, increasing the risk of overdose and fatalities. Furthermore, the clandestine production and distribution of xylazine for recreational purposes often involve varying levels of purity and potential contamination, compounding the health risks associated with its abuse.

The Rapid Response™ Xylazine 2.0 Test Strip from BTNX is specifically designed for the swift screening of xylazine in liquid/powder samples. This test incorporates an antibody that selectively identifies xylazine. Similar to other harm reduction test strips, it operates on the competitive binding principle. If xylazine is present in the sample at a concentration surpassing the designated cut-off, a singular-colored line will appear in the test region. 

Results Interpretation

Positive - Xylazine Detected: Only one colored line appears in the control region (C). No apparent colored line appears in the test region (T).

Negative – Xylazine Could Not be Detected: Two colored lines appear on the membrane. One line appears in the control region (C) and another line appears in the test region (T).

Test Performance – What has been improved?

BTNX’s initial version of the Rapid Response™ Xylazine Test Strip was evaluated by both the Johns Hopkins Bloomberg School of Public Health, in collaboration with the National Institute of Standards and Technology (NIST), and the Center for Forensic Science Research & Education (CFSRE). Sisco et al. reported that the test consistently detected xylazine in samples with concentration >2 μg/ml and yielded a sensitivity of 97.4%, a specificity of 100%, and an overall accuracy of 98.6%.1 In the CFSRE study, the test demonstrated a sensitivity of 100%, specificity of 85%, and precision of 91%.2 Both studies identified the lidocaine as a cross-reacting substance that may lead to false positives in field. As a result, BTNX continued to improve the specificity to reduce cross-reactivity with Lidocaine and developed the Rapid Response™ Xylazine 2.0 Test Strip. 

Analytical Sensitivity Comparison

Although both tests detect xylazine with 100% sensitivity at concentrations above 2 µg/mL, the Rapid Response™ Xylazine 2.0 Test Strip has demonstrated improved sensitivity at lower concentration ranges (see Figure below).  As noted by Sisco, Appley et al. from the study at National Institute of Standards and Technology, this new Xylazine 2.0 Test Strip has an analytical sensitivity of 1 µg/mL.3

Analytical Specificity

Important Note: The following compounds were observed to cross-react with the Xylazine 2.0 Test Strip at the listed concentration. However, these compounds are currently not identified to be common adulterants in the illicit drug supply. 

 

Compounds

Concentration

Clonidine

0.3 mg/mL

Romifidine

0.8 mg/mL

Tizanidine

1 mg/mL

Brimonidine

2 mg/mL

 

The following compounds were spiked into water, respectively, to examine possible cross-reactivity. No false positive was observed at 100 µg/ml.

 

(-)-Ephedrine

Chlorpheniramine

Oxalic Acid

(+)-Naproxen

Creatine

Penicillin-G

(+/-)-Ephedrine

Dextromethorphan

Pheniramine

4-Dimethyllaminoantiyrine

Dextrorphan tartrate

Phenothiazine

Acetaminophen

Dopamine

Procaine

Acetone

Erythromycin

Protonix

Albumin

Ethanol

Pseudoephedrine

Amitriptyline

Furosemide

Quinidine

Ampicillin

Glucose

Ranitidine

Aspartame

Guaiacol Glyceryl Ether

Sertraline

Aspirin

Hemoglobin

Tyramine

Benzocaine

Imipramine

Trimeprazine

Bilirubin

(+/-)-Isoproterenol

Venlafaxine

b-Phenylethyl-amine

Methadone

Ibuprofen

Caffeine

Vitamin C (Ascorbic Acid)

Cocaine

Chloroquine

Methamphetamine

Clonidine

Brimonidine

Romifidine

Tizanidine

 

Some common cutting agents and opioids were tested at higher concentrations. No false positives were observed at the concentrations listed below. Lidocaine does not cross react with the Rapid Response™ Xylazine 2.0 Test Strip.3

 

Compounds

Concentration

Lidocaine

5 mg/mL

Quinine

5 mg/mL

Diphenhydramine

10 mg/mL

Caffeine

10 mg/mL

Phenacetin

5 mg/mL

Acetaminophen

5 mg/mL

Dimethylsulphone

10 mg/mL

Levamisole

10 mg/mL

Doxylamine

5 mg/mL

Disopyramide

3 mg/mL

MDMA

5 mg/mL

Methamphetamine

5 mg/mL

Ordering Information

Rapid Response™ Xylazine 2.0 Test Strip is now available to purchase as Rapid Response™ Xylazine Test Strip (Liquid / Powder) under the product code XYL-18S2-100 from Lochness Medical Supplies in the USA and BTNX Inc. in Canada and the international market. 
All XYL-18S2-100 kits with expiration dates on or after 2026-01-17 (YYYY-MM-DD) will contain the Xylazine 2.0 strip and with a Lot number beginning with DOAB.

References
  1. Sisco E, Nestadt DF, Bloom MB, et al. Understanding sensitivity and cross-reactivity of xylazine lateral flow immunoassay test strips for drug checking applications. Drug Test Anal. Published online December 3, 2023. doi:10.1002/dta.3612
  2. Evaluation of xylazine test strips (BTNX) for drug checking purposes. The Center for Forensic Science Research & Education. https://www.cfsre.org/nps-discovery/drug-checking/evaluation-of-xylazine-test-strips-btnx-for-drug-checking-purposes
  3. Sisco E, Appley MG, Pyfrom EM, Banta-Green CJ, Shover CL, Molina CA, et al. Beyond Fentanyl Test Strips: Investigating Other Urine Drug Test Strips for Drug Checking Applications. ChemRxiv. 2024; doi:10.26434/chemrxiv-2024-c39kc This content is a preprint and has not been peer-reviewed.
Back to Blogs
Lochness Medical Supplies Inc.
2775 Broadway Suite 100
Buffalo, NY 14227 USA
Tel: 1-888-506-2658
Fax: 905-248-3501

Contact Us

  • Return Policy
  • Terms of Service
  • Privacy Statement

Account

  • My Account
  • Order History

Quick Links

  • Home
  • About Us
  • Contact Us
  • Career Opportunities
  • Blog
Disclaimer: The health-related information on our website is meant for basic informational purposes only and it is not intended to serve as medical advice. While we make every effort to provide you the most accurate and up-to-date information about our products, please note that actual products may differ slightly from specifications or the pictures. Some products or services referred to in this website may not be avaliable in your territory.
© Copyright 2025. All Rights Reserved.